forked from msvsphere/leapp-repository
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
60 lines
2.4 KiB
60 lines
2.4 KiB
10 months ago
|
from leapp.models import fields, Model
|
||
|
from leapp.topics import SystemInfoTopic
|
||
|
|
||
|
|
||
|
class MultipathConfigOption(Model):
|
||
|
"""Model representing information about a multipath configuration option"""
|
||
|
topic = SystemInfoTopic
|
||
|
|
||
|
name = fields.String(default='')
|
||
|
value = fields.String(default='')
|
||
|
|
||
|
|
||
|
class MultipathConfig(Model):
|
||
|
"""Model representing information about a multipath configuration file"""
|
||
|
topic = SystemInfoTopic
|
||
|
|
||
|
pathname = fields.String()
|
||
|
"""Config file path name"""
|
||
|
|
||
|
default_path_checker = fields.Nullable(fields.String())
|
||
|
config_dir = fields.Nullable(fields.String())
|
||
|
"""Values of path_checker and config_dir in the defaults section.
|
||
|
None if not set"""
|
||
|
|
||
|
default_retain_hwhandler = fields.Nullable(fields.Boolean())
|
||
|
default_detect_prio = fields.Nullable(fields.Boolean())
|
||
|
default_detect_checker = fields.Nullable(fields.Boolean())
|
||
|
reassign_maps = fields.Nullable(fields.Boolean())
|
||
|
"""True if retain_attached_hw_handler, detect_prio, detect_path_checker,
|
||
|
or reassign_maps is set to "yes" in the defaults section. False
|
||
|
if set to "no". None if not set."""
|
||
|
|
||
|
hw_str_match_exists = fields.Boolean(default=False)
|
||
|
ignore_new_boot_devs_exists = fields.Boolean(default=False)
|
||
|
new_bindings_in_boot_exists = fields.Boolean(default=False)
|
||
|
unpriv_sgio_exists = fields.Boolean(default=False)
|
||
|
detect_path_checker_exists = fields.Boolean(default=False)
|
||
|
overrides_hwhandler_exists = fields.Boolean(default=False)
|
||
|
overrides_pg_timeout_exists = fields.Boolean(default=False)
|
||
|
queue_if_no_path_exists = fields.Boolean(default=False)
|
||
|
all_devs_section_exists = fields.Boolean(default=False)
|
||
|
"""True if hw_str_match, ignore_new_boot_devs, new_bindings_in_boot,
|
||
|
detect_path_checker, or unpriv_sgio is set in any section,
|
||
|
if queue_if_no_path is included in the features line in any
|
||
|
section or if hardware_handler or pg_timeout is set in the
|
||
|
overrides section. False otherwise"""
|
||
|
|
||
|
all_devs_options = fields.List(fields.Model(MultipathConfigOption),
|
||
|
default=[])
|
||
|
"""options in an all_devs device configuration section to be converted to
|
||
|
an overrides section"""
|
||
|
|
||
|
|
||
|
class MultipathConfFacts(Model):
|
||
|
"""Model representing information from multipath configuration files"""
|
||
|
topic = SystemInfoTopic
|
||
|
|
||
|
configs = fields.List(fields.Model(MultipathConfig), default=[])
|
||
|
"""List of multipath configuration files"""
|