You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
128 lines
6.8 KiB
128 lines
6.8 KiB
2 days ago
|
From 758cd9ddac150342dbac49ed4c80c68531c169b7 Mon Sep 17 00:00:00 2001
|
||
|
From: =?UTF-8?q?Zbigniew=20J=C4=99drzejewski-Szmek?= <zbyszek@in.waw.pl>
|
||
|
Date: Fri, 28 Jul 2023 17:54:59 +0200
|
||
|
Subject: [PATCH] manager: fix reloading in reload-or-restart --marked
|
||
|
|
||
|
bus_unit_queue_job_one has two callers:
|
||
|
- bus_unit_queue_job which would do the appropriate transormations
|
||
|
to turn JOB_TRY_RESTART into JOB_TRY_RELOAD,
|
||
|
- and method_enqueue_marked_jobs which did not.
|
||
|
In effect, method_enqueue_marked_jobs() would queue restart jobs for
|
||
|
units which has Markers= needs-reload or needs-restart.
|
||
|
|
||
|
When the chunk of code which does the transformations is moved from
|
||
|
bus_unit_queue_job to bus_unit_queue_job_one, there is no change for
|
||
|
bus_unit_queue_job, and method_enqueue_marked_jobs is fixed.
|
||
|
|
||
|
The additional checks that are done seem reasonable to do from
|
||
|
method_enqueue_marked_jobs: we shouldn't be restarting units which are
|
||
|
configured to not allow that, or force unwanted start of dbus-broker.
|
||
|
|
||
|
(cherry picked from commit 8ea8e23f4013dbc4f4a66c81eb786f0505434f2e)
|
||
|
|
||
|
Resolves: RHEL-40878
|
||
|
---
|
||
|
src/core/dbus-unit.c | 82 ++++++++++++++++++++++----------------------
|
||
|
1 file changed, 41 insertions(+), 41 deletions(-)
|
||
|
|
||
|
diff --git a/src/core/dbus-unit.c b/src/core/dbus-unit.c
|
||
|
index 49eacc977c..b45b3fdb53 100644
|
||
|
--- a/src/core/dbus-unit.c
|
||
|
+++ b/src/core/dbus-unit.c
|
||
|
@@ -1736,6 +1736,47 @@ int bus_unit_queue_job_one(
|
||
|
Job *j, *a;
|
||
|
int r;
|
||
|
|
||
|
+ if (FLAGS_SET(flags, BUS_UNIT_QUEUE_RELOAD_IF_POSSIBLE) && unit_can_reload(u)) {
|
||
|
+ if (type == JOB_RESTART)
|
||
|
+ type = JOB_RELOAD_OR_START;
|
||
|
+ else if (type == JOB_TRY_RESTART)
|
||
|
+ type = JOB_TRY_RELOAD;
|
||
|
+ }
|
||
|
+
|
||
|
+ if (type == JOB_STOP &&
|
||
|
+ IN_SET(u->load_state, UNIT_NOT_FOUND, UNIT_ERROR, UNIT_BAD_SETTING) &&
|
||
|
+ unit_active_state(u) == UNIT_INACTIVE)
|
||
|
+ return sd_bus_error_setf(error, BUS_ERROR_NO_SUCH_UNIT, "Unit %s not loaded.", u->id);
|
||
|
+
|
||
|
+ if ((type == JOB_START && u->refuse_manual_start) ||
|
||
|
+ (type == JOB_STOP && u->refuse_manual_stop) ||
|
||
|
+ (IN_SET(type, JOB_RESTART, JOB_TRY_RESTART) && (u->refuse_manual_start || u->refuse_manual_stop)) ||
|
||
|
+ (type == JOB_RELOAD_OR_START && job_type_collapse(type, u) == JOB_START && u->refuse_manual_start))
|
||
|
+ return sd_bus_error_setf(error,
|
||
|
+ BUS_ERROR_ONLY_BY_DEPENDENCY,
|
||
|
+ "Operation refused, unit %s may be requested by dependency only (it is configured to refuse manual start/stop).",
|
||
|
+ u->id);
|
||
|
+
|
||
|
+ /* dbus-broker issues StartUnit for activation requests, and Type=dbus services automatically
|
||
|
+ * gain dependency on dbus.socket. Therefore, if dbus has a pending stop job, the new start
|
||
|
+ * job that pulls in dbus again would cause job type conflict. Let's avoid that by rejecting
|
||
|
+ * job enqueuing early.
|
||
|
+ *
|
||
|
+ * Note that unlike signal_activation_request(), we can't use unit_inactive_or_pending()
|
||
|
+ * here. StartUnit is a more generic interface, and thus users are allowed to use e.g. systemctl
|
||
|
+ * to start Type=dbus services even when dbus is inactive. */
|
||
|
+ if (type == JOB_START && u->type == UNIT_SERVICE && SERVICE(u)->type == SERVICE_DBUS)
|
||
|
+ FOREACH_STRING(dbus_unit, SPECIAL_DBUS_SOCKET, SPECIAL_DBUS_SERVICE) {
|
||
|
+ Unit *dbus;
|
||
|
+
|
||
|
+ dbus = manager_get_unit(u->manager, dbus_unit);
|
||
|
+ if (dbus && unit_stop_pending(dbus))
|
||
|
+ return sd_bus_error_setf(error,
|
||
|
+ BUS_ERROR_SHUTTING_DOWN,
|
||
|
+ "Operation for unit %s refused, D-Bus is shutting down.",
|
||
|
+ u->id);
|
||
|
+ }
|
||
|
+
|
||
|
if (FLAGS_SET(flags, BUS_UNIT_QUEUE_VERBOSE_REPLY)) {
|
||
|
affected = set_new(NULL);
|
||
|
if (!affected)
|
||
|
@@ -1828,47 +1869,6 @@ int bus_unit_queue_job(
|
||
|
if (r < 0)
|
||
|
return r;
|
||
|
|
||
|
- if (FLAGS_SET(flags, BUS_UNIT_QUEUE_RELOAD_IF_POSSIBLE) && unit_can_reload(u)) {
|
||
|
- if (type == JOB_RESTART)
|
||
|
- type = JOB_RELOAD_OR_START;
|
||
|
- else if (type == JOB_TRY_RESTART)
|
||
|
- type = JOB_TRY_RELOAD;
|
||
|
- }
|
||
|
-
|
||
|
- if (type == JOB_STOP &&
|
||
|
- IN_SET(u->load_state, UNIT_NOT_FOUND, UNIT_ERROR, UNIT_BAD_SETTING) &&
|
||
|
- unit_active_state(u) == UNIT_INACTIVE)
|
||
|
- return sd_bus_error_setf(error, BUS_ERROR_NO_SUCH_UNIT, "Unit %s not loaded.", u->id);
|
||
|
-
|
||
|
- if ((type == JOB_START && u->refuse_manual_start) ||
|
||
|
- (type == JOB_STOP && u->refuse_manual_stop) ||
|
||
|
- (IN_SET(type, JOB_RESTART, JOB_TRY_RESTART) && (u->refuse_manual_start || u->refuse_manual_stop)) ||
|
||
|
- (type == JOB_RELOAD_OR_START && job_type_collapse(type, u) == JOB_START && u->refuse_manual_start))
|
||
|
- return sd_bus_error_setf(error,
|
||
|
- BUS_ERROR_ONLY_BY_DEPENDENCY,
|
||
|
- "Operation refused, unit %s may be requested by dependency only (it is configured to refuse manual start/stop).",
|
||
|
- u->id);
|
||
|
-
|
||
|
- /* dbus-broker issues StartUnit for activation requests, and Type=dbus services automatically
|
||
|
- * gain dependency on dbus.socket. Therefore, if dbus has a pending stop job, the new start
|
||
|
- * job that pulls in dbus again would cause job type conflict. Let's avoid that by rejecting
|
||
|
- * job enqueuing early.
|
||
|
- *
|
||
|
- * Note that unlike signal_activation_request(), we can't use unit_inactive_or_pending()
|
||
|
- * here. StartUnit is a more generic interface, and thus users are allowed to use e.g. systemctl
|
||
|
- * to start Type=dbus services even when dbus is inactive. */
|
||
|
- if (type == JOB_START && u->type == UNIT_SERVICE && SERVICE(u)->type == SERVICE_DBUS)
|
||
|
- FOREACH_STRING(dbus_unit, SPECIAL_DBUS_SOCKET, SPECIAL_DBUS_SERVICE) {
|
||
|
- Unit *dbus;
|
||
|
-
|
||
|
- dbus = manager_get_unit(u->manager, dbus_unit);
|
||
|
- if (dbus && unit_stop_pending(dbus))
|
||
|
- return sd_bus_error_setf(error,
|
||
|
- BUS_ERROR_SHUTTING_DOWN,
|
||
|
- "Operation for unit %s refused, D-Bus is shutting down.",
|
||
|
- u->id);
|
||
|
- }
|
||
|
-
|
||
|
r = sd_bus_message_new_method_return(message, &reply);
|
||
|
if (r < 0)
|
||
|
return r;
|